Sciweavers

ICASSP
2008
IEEE

Air-coupled ultrasound time-of-flight estimation for shipping container cargo verification

14 years 7 months ago
Air-coupled ultrasound time-of-flight estimation for shipping container cargo verification
The falling cost of embedded sensor systems has opened up the possibility of in-transit air-coupled ultrasound interior imaging of shipping container cargo. This new technology could allow for real-time cargo integrity verification and improved shipping and transportation security. This paper takes the initial steps in developing a temperature invariant descriptor by comparing three time-of-flight (TOF) estimation methods from the literature using in situ data. The methods compared are matched filter, leading edge envelope line fit, and a simple envelope half-peak intercept. The results show that the simple half-peak intercept method provided the most consistent TOF estimate with respect to overlapping pulse data.
Patrick McVittie, Les E. Atlas
Added 30 May 2010
Updated 30 May 2010
Type Conference
Year 2008
Where ICASSP
Authors Patrick McVittie, Les E. Atlas
Comments (0)