Sciweavers

TCAD
2008

Bridging Fault Test Method With Adaptive Power Management Awareness

14 years 10 days ago
Bridging Fault Test Method With Adaptive Power Management Awareness
Abstract--A key design constraint of circuits used in handheld devices is the power consumption, mainly due to battery life limitations. Adaptive power management (APM) techniques aim to increase the battery life of such devices by adjusting the supply voltage and operating frequency, and thus the power consumption, according to the workload. Testing for resistive bridging defects in APM-enabled designs raises a number of challenges due to their complex analog behavior. Testing at more than one supply voltage setting can be employed to improve defect coverage in such systems, however, switching between several supply voltage settings has a detrimental impact on the overall cost of test. This paper proposes a multi-Vdd automatic test generation method which delivers 100% resistive bridging defect coverage and also a way of reducing the number of supply voltage settings required during test through test point insertion. The proposed techniques have been experimentally validated using a n...
S. Saqib Khursheed, Urban Ingelsson, Paul M. Rosin
Added 15 Dec 2010
Updated 15 Dec 2010
Type Journal
Year 2008
Where TCAD
Authors S. Saqib Khursheed, Urban Ingelsson, Paul M. Rosinger, Bashir M. Al-Hashimi, Peter Harrod
Comments (0)