High Quality Autostereoscopic Surgical Display Using Anti-aliased Integral Videography Imaging

15 years 21 days ago
High Quality Autostereoscopic Surgical Display Using Anti-aliased Integral Videography Imaging
This paper presents an autostereoscopic three-dimensional (3-D) surgical display with high quality integral videography (IV) rendering algorithm. IV is an animated extension of integral photography, which provides 3-D images without using any supplementary glasses or tracking devices. Despite IV's many advantages, the quality of its spatial image has thus far been poor. We developed a high quality image rendering method with oversampling technique for enhancing the resolution of elemental IV image and low-passfilter for smoothing the image. Furthermore, we manufactured a high-resolution IV display for evaluating the feasibility of proposed method. The experimental results show the quality of anti-aliased IV image is improved. We also integrated the developed IV image into image-guided surgery display system. This approach will allow us to acquire the optimum process to produce high quality 3-D image for planning and guidance of minimally invasive surgery.
Hongen Liao, Daisuke Tamura, Makoto Iwahara, Nobuh
Added 15 Nov 2009
Updated 15 Nov 2009
Type Conference
Year 2004
Where MICCAI
Authors Hongen Liao, Daisuke Tamura, Makoto Iwahara, Nobuhiko Hata, Takeyoshi Dohi