A New Class of Distance Measures for Registration of Tubular Models to Image Data
In some registration applications additional user knowledge is available, which can improve and accelerate the registration process, especially for non-rigid registration. This is particularly important in the transfer of pre-operative plans to the operating room, e.g. for navigation. In case of tubular structures, such as vessels, a geometric representation can be extracted via segmentation and skeletonization. We present a new class of distance measures based on global filter kernels to compare such models efficiently with image data. The approach is validated in a non-rigid registration application with Powerdoppler ultrasound data.
Thomas Lange, Hans Lamecker, Michael Hünerbei
Added 29 Oct 2010
Updated 29 Oct 2010
Type Conference
Year 2007
Where BILDMED
Authors Thomas Lange, Hans Lamecker, Michael Hünerbein, Sebastian Eulenstein, Siegfried Beller, Peter-Michael Schlag
Comments (0)