Sciweavers

BILDMED
2009

Triple-Modality Normalized Mutual Information Based Medical Image Registration of Cardiac PET/CT and SPECT Images

13 years 9 months ago
Triple-Modality Normalized Mutual Information Based Medical Image Registration of Cardiac PET/CT and SPECT Images
Abstract. An extension of the normalized mutual information similarity measurement was proposed to register cardiac PET/CT and SPECT images representing coronary artery disease in the heart. 23 PET/CT images obtained by a hybrid camera, and their corresponding SPECT were processed. The SPECT was registered to the PET/CT image pairs by a triple NMI based auto-registration. For validation and comparison an triple MI based registration among the PET-SPECT-CT images was performed. Two further dual NMI based auto-registrations between the SPECT-CT and SPECT-PET were performed as well. Based on the comparative results gained by a medical expert, our triple NMI method gave the best transformation parameters with a minimal number of iterations to superimpose the images.
Laszlo Papp, Maaz Zuhayra, Reinhard Koch
Added 16 Feb 2011
Updated 16 Feb 2011
Type Journal
Year 2009
Where BILDMED
Authors Laszlo Papp, Maaz Zuhayra, Reinhard Koch
Comments (0)