Sciweavers

NTMS
2015
IEEE

Using thermal transients at the outlet of electrical water heaters to recognise consumption patterns for heating schedule optimi

8 years 7 months ago
Using thermal transients at the outlet of electrical water heaters to recognise consumption patterns for heating schedule optimi
—In the midst of environmental concerns, and soaring energy costs and energy shortages, the efficiency of electrical household water heaters (EWHs) has been identified as an area with significant potential for savings. The benefits of applying optimised scheduling control for EWHs has been proven by various studies, however, little has been done to measure individual behaviour. This paper presents an alternative to the invasive and expensive solution of using water flow meters. A hardware and algorithmic solution is presented that uses thermal transients at the outlet of an EWH to measure consumption patterns. The results show that the approach is able to detect usage events with an accuracy of 91%. Despite the challenges related to thermal inaccuracies, event durations are estimated to within 2 minutes accuracy 79% of the time.
P. J. C. Nel, M. J. Thinus Booysen, B. van der Mer
Added 15 Apr 2016
Updated 15 Apr 2016
Type Journal
Year 2015
Where NTMS
Authors P. J. C. Nel, M. J. Thinus Booysen, B. van der Merwe
Comments (0)