Sciweavers

MICCAI
2003
Springer
15 years 11 days ago
C-Mode Real Time Tomographic Reflection for a Matrix Array Ultrasound Sonic Flashlight
George D. Stetten, Aaron Cois, Wilson Chang, Damio...
MICCAI
2003
Springer
15 years 11 days ago
Cortical Shift Tracking Using a Laser Range Scanner and Deformable Registration Methods
A novel brain shift tracking protocol is introduced in this paper which utilizes laser range scan (LRS) data and 2D deformable image registration. This protocol builds on previous ...
Tuhin K. Sinha, Valerie Duay, Benoit M. Dawant, Mi...
MICCAI
2003
Springer
15 years 11 days ago
Pathology Growth Model Based on Particles
Virtual reality based surgical simulators offer the possibility to provide training on a wide range of findings of different pathologies. Current research aims at a high fidelity h...
Raimundo Sierra, Michael Bajka, Gábor Sz&ea...
MICCAI
2003
Springer
15 years 11 days ago
Morphometric Analysis of Brain Structures for Improved Discrimination
Abstract. We perform discriminative analysis of brain structures using morphometric information. Spherical harmonics technique and point distribution model are used for shape descr...
Li Shen, James Ford, Fillia Makedon, Yuhang Wang, ...
MICCAI
2003
Springer
15 years 11 days ago
Computed Cleansing for Virtual Colonoscopy Using a Three-Material Transition Model
Virtual colonoscopy is a non-invasive technique for the detection of polyps. Currently, a clean colon is required; as without cleansing the colonic wall cannot be segmented. Enhanc...
Iwo Serlie, Roel Truyen, Jasper Florie, Frits H. P...
MICCAI
2003
Springer
15 years 11 days ago
Topological Correction of Subcortical Segmentation
Abstract. We propose a method for automatically correcting the spherical topology of any segmentation under any digital connectivity. A multiple region growing process, concurrentl...
Florent Ségonne, W. Eric L. Grimson, Bruce ...
MICCAI
2003
Springer
15 years 11 days ago
Intensity-Based 2D-3D Spine Image Registration Incorporating One Fiducial Marker
In this paper, we propose a hybrid similarity measure for 2D-3D image registration that is a weighted combination of an intensitybased image similarity measure and a point-based me...
Daniel B. Russakoff, Torsten Rohlfing, Ramin Shahi...
MICCAI
2003
Springer
15 years 11 days ago
Geostatistical Medical Image Registration
Abstract. We propose a novel approach to landmark-based medical image registration based on the geostatical method of Kriging prediction. Our method exploits the spatial statistica...
Carl-Fredrik Westin, Carlos Alberola-López,...
MICCAI
2003
Springer
15 years 11 days ago
Robust and Automatic Calibration Method for 3D Freehand Ultrasound
This paper describes a new robust and fully automatic method for calibration of three-dimensional (3D) freehand ultrasound. 3D Freehand ultrasound consists in mounting a position s...
François Rousseau, Pierre Hellier, Christia...
MICCAI
2003
Springer
15 years 11 days ago
Extraction and Application of Expert Priors to Combine Multiple Segmentations of Human Brain Tissue
Abstract. This paper evaluates strategies to combine multiple segmentations of the same image, generated for example by different segmentation methods or by different human experts...
Torsten Rohlfing, Daniel B. Russakoff, Calvin R. M...