Sciweavers

MICCAI
2005
Springer

Finite Element Model of Cornea Deformation

15 years 1 months ago
Finite Element Model of Cornea Deformation
Abstract. Cornea surgeons have observed that changes in cornea curvature can follow cataract surgery and cause astigmatism. The placement of surgical incisions has been shown to influence these curvature changes. Though empirical data has been collected about this phenomenon, a biomechanical model has not been employed in predicting post-surgical outcomes. This work implemented an incised finite element model of the eye to investigate factors influencing corneal shape after surgery. In particular, the effects of eye muscle forces and intra-ocular pressure were simulated. Cornea shape change was computed via finite element analysis, and the resulting change in cornea curvature was measured by fitting quadratic curves to the horizontal and vertical meridians of the cornea. Results suggest that these two sources of deforming force counteract each other and contribute to astigmatism in perpendicular directions.
Jessica R. Crouch, John C. Merriam, Earl R. Crouch
Added 15 Nov 2009
Updated 15 Nov 2009
Type Conference
Year 2005
Where MICCAI
Authors Jessica R. Crouch, John C. Merriam, Earl R. Crouch
Comments (0)