Sciweavers

ICCAD
2006
IEEE

Precise identification of the worst-case voltage drop conditions in power grid verification

14 years 9 months ago
Precise identification of the worst-case voltage drop conditions in power grid verification
– Identifying worst-case voltage drop conditions in every module supplied by the power grid is a crucial problem in modern IC design. In this paper we develop a novel methodology for power grid verification which is based on accurately constructing the space of current variations of the supplied modules and locating its precise points that yield the worst-case voltage drop conditions. The construction of the current space is performed via plain simulation and statistical extrapolation using results from extreme value theory. The method overcomes limitations of past methods which either relied on loosely bounding the worst-case voltage abstracted the current space in a vague and incomplete set of bound-type constraints. Experimental results verify the potential of the proposed method to identify worst-case conditions and demonstrate the pessimism inherent in previous bound-type approaches.
Nestoras E. Evmorfopoulos, Dimitris P. Karampatzak
Added 16 Mar 2010
Updated 16 Mar 2010
Type Conference
Year 2006
Where ICCAD
Authors Nestoras E. Evmorfopoulos, Dimitris P. Karampatzakis, Georgios I. Stamoulis
Comments (0)