Sciweavers

VMV
2008

Statistical analysis of Multi-Material Components using Dual Energy CT

14 years 1 months ago
Statistical analysis of Multi-Material Components using Dual Energy CT
This work describes a novel method for statistical analysis of multi-material components. The application scenario is industrial 3D X-ray computed tomography, emphasizing metrology of artefact affected plastics-metal components. The presented work makes use of dual energy CT data acquisition for artefact reduction, in order to optimize CT scans of multi-material components. Using statistical analysis, information on uncertainty is introduced, which allows detailed characterizations of single materials as well as material interfaces. The major contribution of this paper is the development of a specific pipeline based on the dual exposure technique of dual energy CT. After prefiltering and multi-scan fusion, the statistical analysis step computes probability volumes of the fused data using a local histogram analysis technique. The application areas as well as the achieved precision of the presented method are depicted using a test specimen and a real world component.
Christoph Heinzl, Johann Kastner, Torsten Möl
Added 30 Oct 2010
Updated 30 Oct 2010
Type Conference
Year 2008
Where VMV
Authors Christoph Heinzl, Johann Kastner, Torsten Möller, Eduard Gröller
Comments (0)