Sciweavers

MICCAI
2008
Springer
15 years 1 months ago
Physical-Space Refraction-Corrected Transmission Ultrasound Computed Tomography Made Computationally Practical
Abstract. Transmission Ultrasound Computed Tomography (CT) is strongly affected by the acoustic refraction properties of the imaged tissue, and proper modeling and correction of th...
Shengying Li, Klaus Mueller, Marcel Jackowski, ...
MICCAI
2008
Springer
15 years 1 months ago
Assessment of Reliability of Multi-site Neuroimaging Via Traveling Phantom Study
Abstract. This paper describes a framework for quantitative analysis of neuroimaging data of traveling human phantoms used for cross-site validation. We focus on the analysis of ma...
Sylvain Gouttard, Martin Styner, Marcel Prastawa...
MICCAI
2008
Springer
15 years 1 months ago
Estimation of Ground-Glass Opacity Measurement in CT Lung Images
We propose to measure quantitatively the opacity property of each pixel in a ground-glass opacity tumor from CT images. Our method results in an opacity map in which each pixel tak...
Yuanjie Zheng, Chandra Kambhamettu, Thomas Bauer...
MICCAI
2008
Springer
15 years 1 months ago
AutoGate: Fast and Automatic Doppler Gate Localization in B-Mode Echocardiogram
In this paper, we propose a so-called AutoGate algorithm for fast and automatic Doppler gate localization in B-mode echocardiography. The algorithm has two components: 1) cardiac s...
Jin Hyeong Park, Shaohua Kevin Zhou, Costas Simo...
MICCAI
2008
Springer
15 years 1 months ago
Toward a Flexible and Portable CT Scanner
The very hot and power-hungry x-ray filaments in today's computed tomography (CT) scanners constrain their design to be big and stationary. What if we built a CT scanner that ...
Jeff Orchard, John T. W. Yeow
MICCAI
2008
Springer
15 years 1 months ago
Rician Noise Removal by Non-Local Means Filtering for Low Signal-to-Noise Ratio MRI: Applications to DT-MRI
Diffusion-Weighted MRI (DW-MRI) is subject to random noise yielding measures that are different from their real values, and thus biasing the subsequently estimated tensors. The Non...
Nicolas Wiest-Daesslé, Sylvain Prima, Pierr...
MICCAI
2008
Springer
15 years 1 months ago
Parallelized Hybrid TGRAPPA Reconstruction for Real-Time Interactive MRI
Abstract. Real-time parallel MRI reconstruction was demonstrated using a hybrid implementation of the TGRAPPA algorithm. The GRAPPA coefficients were calculated in k-space and appl...
Haris Saybasili, Peter Kellman, J. Andrew Derbys...
MICCAI
2008
Springer
15 years 1 months ago
Wall Motion Classification of Stress Echocardiography Based on Combined Rest-and-Stress Data
In this paper, we present a new framework that performs automated local wall motion analysis based on the combined information derived from a rest and stress sequence (a full stres...
Sarina Mansor, Nicholas P. Hughes, J. Alison Nob...
MICCAI
2008
Springer
15 years 1 months ago
Impact of Rician Adapted Non-Local Means Filtering on HARDI
In this paper we study the impact of denoising the raw high angular resolution diffusion imaging (HARDI) data with the Non-Local Means filter adapted to Rician noise (NLMr). We fir...
Christian Barillot, Maxime Descoteaux, Nicolas Wie...