Sciweavers

SIGMETRICS
2008
ACM

Disk scrubbing versus intra-disk redundancy for high-reliability raid storage systems

14 years 11 days ago
Disk scrubbing versus intra-disk redundancy for high-reliability raid storage systems
Two schemes proposed to cope with unrecoverable or latent media errors and enhance the reliability of RAID systems are examined. The first scheme is the established, widely used disk scrubbing scheme, which operates by periodically accessing disk drives to detect media-related unrecoverable errors. These errors are subsequently corrected by rebuilding the sectors affected. The second scheme is the recently proposed intradisk redundancy scheme which uses a further level of redundancy inside each disk, in addition to the RAID redundancy across multiple disks. Analytic results are obtained assuming Poisson arrivals of random I/O requests. Our results demonstrate that the reliability improvement due to disk scrubbing depends on the scrubbing frequency and the workload of the system, and may not reach the reliability level achieved by a simple IPC-based intra-disk redundancy scheme, which is insensitive to the workload. In fact, the IPC-based intra-disk redundancy scheme achieves essential...
Ilias Iliadis, Robert Haas, Xiao-Yu Hu, Evangelos
Added 15 Dec 2010
Updated 15 Dec 2010
Type Journal
Year 2008
Where SIGMETRICS
Authors Ilias Iliadis, Robert Haas, Xiao-Yu Hu, Evangelos Eleftheriou
Comments (0)