Sciweavers

ICCD
2005
IEEE

Supply Voltage Degradation Aware Analytical Placement

14 years 9 months ago
Supply Voltage Degradation Aware Analytical Placement
Increasingly significant power/ground supply voltage degradation in nanometer VLSI designs leads to system performance degradation and even malfunction. Existing techniques focus on design and optimization of power/ground supply networks. In this paper, we propose supply voltage degradation aware placement, e.g., to reduce maximum supply voltage degradation by relocation of supply current sources. We represent supply voltage degradation at a P/G node as a function of supply currents and effective impedances (i.e., effective resistances in DC analysis) in a P/G network, and integrate supply voltage degradation in an analytical placement objective. For scalability and efficiency improvement, we apply random-walk, graph contraction and interpolation techniques to obtain effective resistances. Our experimental results show an average 20.9% improvement of worst-case voltage degradation and
Andrew B. Kahng, Bao Liu, Qinke Wang
Added 16 Mar 2010
Updated 16 Mar 2010
Type Conference
Year 2005
Where ICCD
Authors Andrew B. Kahng, Bao Liu, Qinke Wang
Comments (0)