Sciweavers

VLSID
2000
IEEE

Inductance Characterization of Small Interconnects Using Test-Signal Method

14 years 4 months ago
Inductance Characterization of Small Interconnects Using Test-Signal Method
The test signal method can be used to measure and model inductance parameters (self and mutual) of a very small interconnect especially in highdensity IC’s by using a test signal (of small known amplitude and frequency) and a D.C. signal along with a Differential circuit. Other measurement techniques such as LCZ and TDR for measuring inductance parameters are faced with limitations of L values greater than 5nH. The Test Signal Injection compliments this method and facilitates measurement of very low L values, especially those encountered in high speed circuits. This technique is applicable in the designing and benchmarking stage and hence is used to model interconnect couplings before packaging and polysilicon layout. An account of interconnect-substrate effects causing displacement currents that result in selfinductive effects is given. Small interconnects have been modeled as lumped elements of a transmission line to form a full system integrity analysis of the Test Signal Injecti...
Jeegar Tilak Shah, Madhav P. Desai, Sugata Sanyal
Added 01 Aug 2010
Updated 01 Aug 2010
Type Conference
Year 2000
Where VLSID
Authors Jeegar Tilak Shah, Madhav P. Desai, Sugata Sanyal
Comments (0)